These are the Minimum Environmental Criteria, and to access the benefits, the materials chosen for thermal insulation must comply with them
To obtain the 110% Superbonus on thermal insulation interventions, it is mandatory to use heat-insulating panels and felts that comply with the Minimum Environmental Criteria.
In the same way, the increased deduction can also be accessed for roof insulation and also for these interventions CAM products suitable for roofing must be used.
The other current regulations concerning obtaining the 110% Superbonus remain fixed and the option of demolition and complete reconstruction of the building with a view to the Sismabonus remains valid.
The Minimum Environmental Criteria, contained in the Ministerial Decree of 11 October 2017 of the Ministry of the Environment, guide the design and works for the new construction, renovation and maintenance of public buildings. The objective of the MECs is to ensure environmental performance above the industry average from a life cycle perspective.
Originally, the Minimum Environmental Criteria were created to regulate public works, in the context of green procurement, but they are currently also used for private thermal insulation works facilitated with the 110% Superbonus.
Summarizing by points, to obtain the Superbonus, the insulation used must comply with the following criteria:
- must not be produced using flame retardants that are subject to restrictions or prohibitions provided for by applicable national or community regulations
- must not be produced with blowing agents with an ozone-depleting potential of more than zero
- must not be manufactured or formulated using lead catalysts when sprayed or in the course of plastic foaming
- if produced from an expandable polystyrene resin, the blowing agents must be less than 6% of the weight of the finished product
- if made of mineral wool, these must comply with Note Q or Note R of Regulation (EC) No 1272/2008 (CLP) as amended.
- if the finished product contains one or more of the following components (cellulose, glass wool, rock wool, expanded perlite, polyester fibres, expanded polystyrene, extruded polystyrene, polyurethane foam, polyurethane agglomerate, rubber agglomerates, reflective aluminium insulation) listed in the table contained in paragraph 2.4.2.9 “Thermal and acoustic insulation”, these must be made of recycled and/or recovered material according to the minimum quantities indicated in the table, measured on the weight of the finished product.
The Ministerial Decree of 11 October 2017 also contains, in paragraph 2.4.1, the CAM common to all building components.
The percentage of recycled material can be demonstrated by:
- a Type III Environmental Product Declaration (EPD), compliant with UNI EN 15804 and ISO 14025, as EPDItaly© or equivalent
- a product certification issued by a conformity assessment body that certifies the recycled content through the explanation of the mass balance, such as ReMade in Italy®, Plastic Second Life or equivalent
- a product certification issued by a conformity assessment body that certifies the recycled content through the explication of the mass balance which consists in the verification of a self-declared environmental declaration, compliant with the ISO 14021 standard
- an inspection report issued by an inspection body, in accordance with ISO/IEC 17020:2012, certifying the content of recovered or recycled material in the product. This solution must be adopted if the manufacturing company does not have the certifications and provides for an inspection activity during the execution of the works